Thread: IANTD tables
View Single Post
Old April 21st, 2007, 11:02 PM   #3 (permalink)
prharris(Offline)
New Member
 
prharris's Avatar
 

Join Date: Nov 2005
Location: Plymouth
Posts: 91
prharris is a jewel in the roughprharris is a jewel in the roughprharris is a jewel in the roughprharris is a jewel in the rough

Quote: (Originally Posted by Steve Geraghty)View Post
think proplanner was used , no gradient factors


Algorithm: Buhlmann ZHL16
Number of tissues: 16
Compartments: 16
N2 half-times(mins):
4.0, 8.0, 12.5, 18.5, 27.0, 38.3, 54.3, 77.0, 109.0, 146.0, 187.0, 239.0,
305.0, 390.0, 498.0, 635.0
He half-times(mins).
1.51, 3.02, 4.72, 6.99, 10.21, 14.48, 20.53, 29.11, 41.20, 55.19, 70.69,
90.34, 115.29, 147.42, 188.24, 240.03

Altitude range: Maximum= 1400mbar Minimum= 0 mbar.

Depth safety factor: (DEPTH x 1.03) + 1metre
There is some padding over the straight Buhlmann tables, I'm not sure if it matches the output from Proplanner.
There was an undocumented switch (which escapes me at the moment) to turn off the padding in PP.

r
Paul
 
Digg this Post!Add Post to del.icio.us
Reply With Quote